Post Top Ad

Friday, September 22, 2023

on video ||hospital lighting wiring diagram||two way switch wiring connection


 Light Control Circuit by Switches for Patient in Hospital Rooms

We call it “Hospital wiring circuit” by using only switches and lamps to control the lighting density of bulbs in a room especially for admitted patients in the hospital. Although, we can control the lighting density by using a light dimmer switch with led lamps or PWM controller with LED. In this circuit, we only use normal ON/OFF switches to control the lighting in three ways i.e. Maximum light, medium light and minimum light.


Related Wiring Tutorial: Hotel Wiring Circuit – Bell Indicator Circuit for Hotelling

Following is another wiring circuit for light control using light dimmer switches. Keep in mind that light dimmer switches will work only with dimmable led lamps while non-dimmable light lamps wont work with dimmer circuits and switches.


Procedure:

First of all, turn off the main breaker to ensure the main supply is switched OFF.

Connect all the switches to the grounding / grounding terminals (not shown in the fig)

Connect the Neutral wire from MCB directly to the first terminal of lamp #1 and then connect to the upper terminal of SPDT (2-Way) switch as shown in the fig.

Connect the live (line or phase) wire to the lower terminals of SPST (1-way) and SPDT (2-way) switches.

Connect the lamp #1 to the upper terminal of SPST switch.

Connect the lamp #2 to the common (middle) terminal of SPDT switch shown by blue wire in the circuit diagram.

Do the proper earthing and grounding according to your local area codes.

Now turn on the main breaker to ensure the circuit is working properly according to your needs.

Related Wiring Tutorial: Hostel Wiring Circuit Diagram and Working

Working:

The hospital circuit for lighting control is working as follows:


No Light:

SPST OFF and SPDT Up. Both lamps are turned OFF as the circuit is not completed yet.


Maximum Light:

SPST ON and SPST Up. Both lamps are glowing at rated density as both bulbs are connected in parallel and getting the rated voltage.

Medium Light:

SPST ON and SPST Down. Only one lamp is turned ON. The first lamp is glowing while the second one is turned OFF.


Minimum Light:

SPST OFF and SPST Down. Both lamps are dim i.e. They are connected in series and getting half of the rated voltage.


 Light Control Circuit by Switches for Patient in Hospital Rooms

We call it “Hospital wiring circuit” by using only switches and lamps to control the lighting density of bulbs in a room especially for admitted patients in the hospital. Although, we can control the lighting density by using a light dimmer switch with led lamps or PWM controller with LED. In this circuit, we only use normal ON/OFF switches to control the lighting in three ways i.e. Maximum light, medium light and minimum light.


Related Wiring Tutorial: Hotel Wiring Circuit – Bell Indicator Circuit for Hotelling

Following is another wiring circuit for light control using light dimmer switches. Keep in mind that light dimmer switches will work only with dimmable led lamps while non-dimmable light lamps wont work with dimmer circuits and switches.


Procedure:

First of all, turn off the main breaker to ensure the main supply is switched OFF.

Connect all the switches to the grounding / grounding terminals (not shown in the fig)

Connect the Neutral wire from MCB directly to the first terminal of lamp #1 and then connect to the upper terminal of SPDT (2-Way) switch as shown in the fig.

Connect the live (line or phase) wire to the lower terminals of SPST (1-way) and SPDT (2-way) switches.

Connect the lamp #1 to the upper terminal of SPST switch.

Connect the lamp #2 to the common (middle) terminal of SPDT switch shown by blue wire in the circuit diagram.

Do the proper earthing and grounding according to your local area codes.

Now turn on the main breaker to ensure the circuit is working properly according to your needs.

Related Wiring Tutorial: Hostel Wiring Circuit Diagram and Working

Working:

The hospital circuit for lighting control is working as follows:


No Light:

SPST OFF and SPDT Up. Both lamps are turned OFF as the circuit is not completed yet.


Maximum Light:

SPST ON and SPST Up. Both lamps are glowing at rated density as both bulbs are connected in parallel and getting the rated voltage.

Medium Light:

SPST ON and SPST Down. Only one lamp is turned ON. The first lamp is glowing while the second one is turned OFF.


Minimum Light:

SPST OFF and SPST Down. Both lamps are dim i.e. They are connected in series and getting half of the rated voltage.

No comments:

Post a Comment

Post Top Ad

Pages