House wiring refers to the electrical wiring and installation of electrical systems in residential buildings. It includes the wiring for lighting, power distribution, and other electrical appliances in a home.


In this circuit I will explain to you how to make a wiring diagram in a typical home.

Watching this video will give you a better understanding of how to wire from a DB board inside a house.

Here's how to put one together for use with your two bedroom and living room, kitchen and outdoor wiring.


**For a room with a 5A plug base and light, power is supplied from the DB board via a 10A MCB using a 1 sq mm cable.


**Two 13A plug bases are powered from the DB Board via a 16 A MCB using a 2.5 sq mm cable.


**2.5 sq mm cable is used for earth wire.


**It is mandatory to bury the earth through the earth pipe using the earth wire from the earth link.


**It is advisable to use a 6 sq mm cable for the main supply of the DB Box.


MCB(Miniature Circuit Breaker)


RCCB(Residual Current Circuit Breaker)

 

House wiring refers to the electrical wiring and installation of electrical systems in residential buildings. It includes the wiring for lighting, power distribution, and other electrical appliances in a home.


In this circuit I will explain to you how to make a wiring diagram in a typical home.

Watching this video will give you a better understanding of how to wire from a DB board inside a house.

Here's how to put one together for use with your two bedroom and living room, kitchen and outdoor wiring.


**For a room with a 5A plug base and light, power is supplied from the DB board via a 10A MCB using a 1 sq mm cable.


**Two 13A plug bases are powered from the DB Board via a 16 A MCB using a 2.5 sq mm cable.


**2.5 sq mm cable is used for earth wire.


**It is mandatory to bury the earth through the earth pipe using the earth wire from the earth link.


**It is advisable to use a 6 sq mm cable for the main supply of the DB Box.


MCB(Miniature Circuit Breaker)


RCCB(Residual Current Circuit Breaker)

 