How to wire a DIN rail distribution board - practical demonstration (South Africa).
This is a lab setup for the practical demonstration of wiring a distribution board with several loads - lights, geyser, and plugs. Loads protected by earth leakage (RCD) and over current circuit breaker protection.
A distribution board (also called a distribution board, breaker panel, electrical panel, DB board, or DB box) is a power distribution system that divides the power supply into auxiliary circuits and provides protective fuses or circuit breakers for each circuit. is a component of general enclosure. Usually the main switch, and on modern boards, also incorporates one or more residual current devices (RCDs) or residual current circuit breakers (RCBOs) with overcurrent protection. In the UK, distribution boards designed for domestic use are known as consumer units.
distribution boards are typically housed in a sheet metal enclosure with circuit breakers arranged in two rows accessible from the front. Some distribution boards have a door that covers the breaker switch handle, but all distribution boards have a dead panel on the front. That is, the front of the enclosure (with or without a door) prevents the operator of the circuit breaker from contacting live electrical components inside. The busbar carries the current from the incoming line (hot) conductor to the breaker. The breaker is secured to the bus either with a bolt-on connection (using screws) or a plug-in connection using retaining clips. Distribution boards are more common in commercial and industrial applications and employ bolt-on breakers. Residential and light commercial panels are commonly called load centers and employ plug-in breakers. The neutral wire is secured to the neutral bus using screw terminals. The branch circuit bonding conductor is fixed to a terminal block mounted directly on the switchboard enclosure, and the terminal block itself is grounded. When the cover is removed to expose the cables during maintenance of the distribution board, it is common for the live parts of the distribution board in the United States to be exposed. In a Canadian service-entry distribution board, the main switch or circuit breaker is located inside a service box that is part of an enclosure that is separate from the rest of the distribution board so that the main switch or circuit breaker is turned off. No live parts are exposed during maintenance. branch circuit.
Breakers are usually arranged in two rows. On US-style boards, breaker locations are numbered left to right from top to bottom along each row. This numbering system is common to many manufacturers of competing breaker panels. Each row is fed from a different phase (A, B, and C below) and a 2-pole or 3-pole common trip breaker can have one pole for each phase. it is common to wire large permanent installations line-to-line. It uses two slots (2 poles) in the panel and gives a voltage of 240 V for split-phase power and 208 V for three-phase power.
The photo to the right shows the inside of distribution board. You can see that there are 3 lead-in wires (2 "hot" wires and 1 neutral) leading up. The neutral wire is connected with all white wires to the left neutral wire busbar and the two hot wires are connected to the main breaker. Below the main breaker are two busbars that carry current between the main breaker and two rows of branch circuit breakers, with red and black hot wires for each circuit. From the left side of the enclosure you can see the three wires (hot black, neutral white and bare ground) going directly to the NEMA 5-15 receptacle where the power cord is plugged. An incoming bare stranded ground wire is visible near the bottom of the neutral busbar. The photo on the left shows a dual panel configuration with the main panel on the right (with the front cover installed) and the sub-panel on the left (with the cover removed). The subpanel is fed by two large hot wires and a neutral wire through an angled conduit near the top of the panel. This configuration appears to exhibit two violations of the current National Electric Code. The main panel has no ground conductor (here it is fed through the subpanel instead), and the subpanel neutral bar is glued to the ground bar (they must be separate). The bar after the first service disconnection (in this case the main panel).
A common design fuse box employed in homes built between 1940 and 1965 used four plug fuses (i.e., Edison-based) for branch circuits and cartridge fuses for purposes such as: It was a 60 amp fuse box containing one or more fuse blocks. Circuits of major electrical appliances. From 1965 onwards, fuller 100 A panels with 3-wire (230 V) service became commonplace. A fuse box can contain a fuse block
and electrical range circuit for the main interrupt, plus a number of plug fuses (Edison base or Type S) for individual circuits.
This photo shows the inside of a typical. The three input phase wires are connected to the busbar through the main switch in the center of the panel. Each side of the panel has two busbars for neutral and ground. The input neutral is connected to the bottom busbar on the right side of the panel and to the neutral busbar on the top left of the panel. The input ground wire is connected to the bottom busbar on the left side of the panel and to the ground busbar on the top right side of the panel. The cover was removed from the lower right neutral bar. A cover is attached to the left neutral bar. On the left side of the phase busbar are two 2-pole RCBOs and two single-pole breakers, one of which is unused. The 2 pole RCBO in the picture is not connected across the two phases, but has a supply side neutral connection coming out behind the phase busbars. On the right side of the busbar are single-pole, 2-pole RCBO, and 3-pole breakers. The illustrated panel contains a large amount of unused space. Manufacturers may be making 18- and 24-position versions of this panel using the same chassis. Large commercial, public, and industrial facilities typically use a three-phase power supply with a distribution board with two vertical rows of breakers. Large installations often use auxiliary switchboards. In both cases, modern boards that handle power up to about 100 A (CU) or 200 A (distribution board) use DIN rail mounted circuit breakers and RCDs. The main distribution board in a facility also usually has a main switch (called an inmer) that switches the phase and neutral wires for the entire power supply. (Note: Income is sometimes called an isolator or marketed as an isolator, but this is problematic because it is not always strictly used as an isolator.) Power is supplied along the busbars for each phase. In a split-phase panel, RCDs can be used to protect groups of circuits because the individual busbars are fed directly from the incoming power. Alternatively, RCBO can be used to provide both overcurrent and residual current protection for a single circuit. Other devices such as transformers (e.g. for bell circuits) and contactors (relays, e.g. for large motors or heating loads) can also be used. New switchboards in the UK are typically sealed to IP2X live parts, even when the cover is removed for maintenance.
BS 7671defines a consumer unit as "a specific type of switchboard with type-tested and coordinated assemblies intended primarily for the control and distribution of electrical energy within the home". These installations typically have single-phase power. 230 V (nominal standard). Until the advent of the mini circuit breaker (MCB), it was historically known as a fuse box because older consumer units used fuses. A normal new home CU used as main panel has 6 to 24 ways for devices (some of them may occupy 2 ways) and 2 or more sections (for non-devices such as alarms). RCD section). RCD protection section for electrical outlets, and RCD protection section for lighting and other built-in equipment). Secondary CUs used in outbuildings typically have 1-4 ways and an RCD. Modern (pre-17th edition wiring rules) CUs typically do not have RCD protection sections other than socket receptacles, but some older CUs were equipped with RCD intercoms. Prior to 1990, RCDs (and split busbars) were not standard on CUs. old rewireable fuse box Fuse boxes typically use cartridge or rewireable fuses without any other protective device, and basic 4-way boxes are very common. Some old boxes are made of brownish-black bakelite, and some have wooden bottoms. These designs are historical, but very common since they were standard equipment on new installations in the 1980s. Fuse holders in these boxes may not protect against accidental contact with live terminals. A typical four-way fuse box usually has two lights and two socket circuits, the socket circuits being subjected to heavy or sustained loads such as immersion heaters or ovens. This arrangement is no longer recommended, but is common in existing installations. Larger boxes with more methods have individual fuses for larger loads such as immersion heaters, ovens and showers.
How to wire a DIN rail distribution board - practical demonstration (South Africa).
This is a lab setup for the practical demonstration of wiring a distribution board with several loads - lights, geyser, and plugs. Loads protected by earth leakage (RCD) and over current circuit breaker protection.
A distribution board (also called a distribution board, breaker panel, electrical panel, DB board, or DB box) is a power distribution system that divides the power supply into auxiliary circuits and provides protective fuses or circuit breakers for each circuit. is a component of general enclosure. Usually the main switch, and on modern boards, also incorporates one or more residual current devices (RCDs) or residual current circuit breakers (RCBOs) with overcurrent protection. In the UK, distribution boards designed for domestic use are known as consumer units.
distribution boards are typically housed in a sheet metal enclosure with circuit breakers arranged in two rows accessible from the front. Some distribution boards have a door that covers the breaker switch handle, but all distribution boards have a dead panel on the front. That is, the front of the enclosure (with or without a door) prevents the operator of the circuit breaker from contacting live electrical components inside. The busbar carries the current from the incoming line (hot) conductor to the breaker. The breaker is secured to the bus either with a bolt-on connection (using screws) or a plug-in connection using retaining clips. Distribution boards are more common in commercial and industrial applications and employ bolt-on breakers. Residential and light commercial panels are commonly called load centers and employ plug-in breakers. The neutral wire is secured to the neutral bus using screw terminals. The branch circuit bonding conductor is fixed to a terminal block mounted directly on the switchboard enclosure, and the terminal block itself is grounded. When the cover is removed to expose the cables during maintenance of the distribution board, it is common for the live parts of the distribution board in the United States to be exposed. In a Canadian service-entry distribution board, the main switch or circuit breaker is located inside a service box that is part of an enclosure that is separate from the rest of the distribution board so that the main switch or circuit breaker is turned off. No live parts are exposed during maintenance. branch circuit.
Breakers are usually arranged in two rows. On US-style boards, breaker locations are numbered left to right from top to bottom along each row. This numbering system is common to many manufacturers of competing breaker panels. Each row is fed from a different phase (A, B, and C below) and a 2-pole or 3-pole common trip breaker can have one pole for each phase. it is common to wire large permanent installations line-to-line. It uses two slots (2 poles) in the panel and gives a voltage of 240 V for split-phase power and 208 V for three-phase power.
The photo to the right shows the inside of distribution board. You can see that there are 3 lead-in wires (2 "hot" wires and 1 neutral) leading up. The neutral wire is connected with all white wires to the left neutral wire busbar and the two hot wires are connected to the main breaker. Below the main breaker are two busbars that carry current between the main breaker and two rows of branch circuit breakers, with red and black hot wires for each circuit. From the left side of the enclosure you can see the three wires (hot black, neutral white and bare ground) going directly to the NEMA 5-15 receptacle where the power cord is plugged. An incoming bare stranded ground wire is visible near the bottom of the neutral busbar. The photo on the left shows a dual panel configuration with the main panel on the right (with the front cover installed) and the sub-panel on the left (with the cover removed). The subpanel is fed by two large hot wires and a neutral wire through an angled conduit near the top of the panel. This configuration appears to exhibit two violations of the current National Electric Code. The main panel has no ground conductor (here it is fed through the subpanel instead), and the subpanel neutral bar is glued to the ground bar (they must be separate). The bar after the first service disconnection (in this case the main panel).
A common design fuse box employed in homes built between 1940 and 1965 used four plug fuses (i.e., Edison-based) for branch circuits and cartridge fuses for purposes such as: It was a 60 amp fuse box containing one or more fuse blocks. Circuits of major electrical appliances. From 1965 onwards, fuller 100 A panels with 3-wire (230 V) service became commonplace. A fuse box can contain a fuse block
and electrical range circuit for the main interrupt, plus a number of plug fuses (Edison base or Type S) for individual circuits.
This photo shows the inside of a typical. The three input phase wires are connected to the busbar through the main switch in the center of the panel. Each side of the panel has two busbars for neutral and ground. The input neutral is connected to the bottom busbar on the right side of the panel and to the neutral busbar on the top left of the panel. The input ground wire is connected to the bottom busbar on the left side of the panel and to the ground busbar on the top right side of the panel. The cover was removed from the lower right neutral bar. A cover is attached to the left neutral bar. On the left side of the phase busbar are two 2-pole RCBOs and two single-pole breakers, one of which is unused. The 2 pole RCBO in the picture is not connected across the two phases, but has a supply side neutral connection coming out behind the phase busbars. On the right side of the busbar are single-pole, 2-pole RCBO, and 3-pole breakers. The illustrated panel contains a large amount of unused space. Manufacturers may be making 18- and 24-position versions of this panel using the same chassis. Large commercial, public, and industrial facilities typically use a three-phase power supply with a distribution board with two vertical rows of breakers. Large installations often use auxiliary switchboards. In both cases, modern boards that handle power up to about 100 A (CU) or 200 A (distribution board) use DIN rail mounted circuit breakers and RCDs. The main distribution board in a facility also usually has a main switch (called an inmer) that switches the phase and neutral wires for the entire power supply. (Note: Income is sometimes called an isolator or marketed as an isolator, but this is problematic because it is not always strictly used as an isolator.) Power is supplied along the busbars for each phase. In a split-phase panel, RCDs can be used to protect groups of circuits because the individual busbars are fed directly from the incoming power. Alternatively, RCBO can be used to provide both overcurrent and residual current protection for a single circuit. Other devices such as transformers (e.g. for bell circuits) and contactors (relays, e.g. for large motors or heating loads) can also be used. New switchboards in the UK are typically sealed to IP2X live parts, even when the cover is removed for maintenance.
BS 7671defines a consumer unit as "a specific type of switchboard with type-tested and coordinated assemblies intended primarily for the control and distribution of electrical energy within the home". These installations typically have single-phase power. 230 V (nominal standard). Until the advent of the mini circuit breaker (MCB), it was historically known as a fuse box because older consumer units used fuses. A normal new home CU used as main panel has 6 to 24 ways for devices (some of them may occupy 2 ways) and 2 or more sections (for non-devices such as alarms). RCD section). RCD protection section for electrical outlets, and RCD protection section for lighting and other built-in equipment). Secondary CUs used in outbuildings typically have 1-4 ways and an RCD. Modern (pre-17th edition wiring rules) CUs typically do not have RCD protection sections other than socket receptacles, but some older CUs were equipped with RCD intercoms. Prior to 1990, RCDs (and split busbars) were not standard on CUs. old rewireable fuse box Fuse boxes typically use cartridge or rewireable fuses without any other protective device, and basic 4-way boxes are very common. Some old boxes are made of brownish-black bakelite, and some have wooden bottoms. These designs are historical, but very common since they were standard equipment on new installations in the 1980s. Fuse holders in these boxes may not protect against accidental contact with live terminals. A typical four-way fuse box usually has two lights and two socket circuits, the socket circuits being subjected to heavy or sustained loads such as immersion heaters or ovens. This arrangement is no longer recommended, but is common in existing installations. Larger boxes with more methods have individual fuses for larger loads such as immersion heaters, ovens and showers.